Sharp MXM264N All About this machine Error Code: All codes A0-01 A0-02 A0-04 A0-10 A0-11 A0-15 A0-20 A0-21 A0-22 E7-01 E7-03 E7-04 E7-07 E7-10 E7-11 E7-14 E7-20 E7-21 E7-28 E7-49 E7-50 E7-55 E7-60 E7-61 E7-65 E7-80 E7-90 E7-91 E7-92 E7-93 E7-94 E7-96 EE-EL EE-EU F1-00 F1-03 F1-10 F1-15 F1-19 F1-20 F1-29 F1-37 F1-50 F1-95 F2-39 F2-40 F2-58 F2-64 F2-70 F2-74 F3-12 F3-22 F3-32 F3-42 F6-00 F6-01 F6-04 F6-21 F6-30 F6-97 F6-98 H2-00 H2-01 H3-00 H3-01 H4-00 H4-01 H5-01 L1-00 L3-00 L4-01 L4-11 L4-30 L4-31 L4-32 L4-35 L4-43 L4-44 L4-56 L6-10 L8-01 L8-02 L8-20 P1-00 P1-01 P1-02 PC-- U1-01 U2-00 U2-05 U2-10 U2-11 U2-24 U2-30 U2-40 U2-41 U2-42 U2-50 U2-60 U2-80 U2-81 U2-90 U2-91 U7-50 U7-51 UC-02 UC-20
  • Code: H3-00
  • Description: Fusing section high temperature trouble (TH_UM) Main heater lamp abnormally high temperature software detection trouble
  • Causes: The fusing temperature exceeds the specified level. Main thermistor trouble PCU PWB trouble Thermistor connector and harness connection trouble Power unit trouble.
  • Remedy: Use SIM44-14 to check the state of the thermistor. Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble. Replace the thermistor. Replace the PCU PWB. Check connection of the thermistor connector and the harness. Replace the power unit.
Used for the following models 8
  • Sharp MXM264FP
  • Sharp MXM264N
  • Sharp MXM264U
  • Sharp MXM314FP
  • Sharp MXM314N
  • Sharp MXM354FP
  • Sharp MXM354N
  • Sharp MXM354U
Error Code
Parts Catalog
Service Mode, Troubleshooting
Downloads Files
Home
Email:
Password:
Sign In
New Register Forgot Password?
Send message to us

Tag » Codice Errore Stampante Sharp H3-00