Sharp MXM453N All About this machine Error Code: All codes A0-01 A0-02 A0-04 A0-10 A0-11 A0-12 A0-15 A0-20 A0-21 A0-22 C1-10 E6-10 E6-11 E6-14 E7-01 E7-03 E7-04 E7-05 E7-06 E7-08 E7-09 E7-10 E7-11 E7-14 E7-20 E7-21 E7-28 E7-29 E7-31 E7-42 E7-46 E7-48 E7-49 E7-50 E7-55 E7-60 E7-61 E7-65 E7-80 E7-90 EE-EC EE-EL EE-EU F1-00 F1-03 F1-08 F1-10 F1-11 F1-15 F1-19 F1-20 F1-21 F1-22 F1-23 F1-31 F1-32 F1-33 F1-34 F1-36 F1-37 F1-38 F1-39 F1-41 F1-43 F1-45 F1-47 F1-50 F2-31 F2-39 F2-40 F2-58 F2-64 F2-70 F2-74 F3-12 F3-22 F6-00 F6-01 F6-04 F6-21 F6-30 F6-97 F6-98 H2-00 H2-02 H3-00 H3-02 H4-00 H4-02 H5-01 H7-10 H7-12 L1-00 L3-00 L4-02 L4-03 L4-04 L4-11 L4-30 L4-31 L4-32 L4-34 L4-43 L4-58 L4-59 L6-10 L8-01 L8-02 L8-20 PC-- U1-01 U2-00 U2-05 U2-10 U2-11 U2-22 U2-23 U2-24 U2-30 U2-50 U2-60 U2-80 U2-81 U2-90 U2-91 U5-00 U5-16 U5-40 U6-00 U6-01 U6-02 U6-09 U6-10 U6-20 U6-21 U6-22 U6-50 U6-51 U7-50 U7-51 UC-02 UC-20
  • Code: H3-00
  • Description: Fusing section high temperature trouble (TH_UM)
  • Causes: The fusing temperature exceeds the specified level. Thermistor trouble. PCU PWB trouble Connection trouble of the fusing section connector and the harness. HL PWB trouble.
  • Remedy: Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble. Replace the thermistor. Replace the PCU PWB. Check connection of the connector and the harness. Replace the HL PWB.
Used for the following models 13
  • Sharp MXM282N
  • Sharp MXM283N
  • Sharp MXM362N
  • Sharp MXM363N
  • Sharp MXM363U
  • Sharp MXM423F
  • Sharp MXM452N
  • Sharp MXM453N
  • Sharp MXM453U
  • Sharp MXM502N
  • Sharp MXM503F
  • Sharp MXM503N
  • Sharp MXM503U
Error Code
Parts Catalog
Service Mode, Troubleshooting
Downloads Files
Home
Email:
Password:
Sign In
New Register Forgot Password?
Send message to us

Tag » Codice Errore Stampante Sharp H3-00