How To Adjust A Water Pressure Switch On A Pump | ESD Waste2Water

How to Adjust a Water Pressure Switch How to Adjust a Water Pressure Switch

The ESD Pressure Pump is regulated by a 30 – 50 PSI Pressure Switch to Turn On & Off the pump.  At times the pressure switch needs to be adjusted.

Steps to Pressure Switch Adjustments on a Pump

  • Step 1: Using a 5/16” Wrench, remove the pressure switch cove
    • SAFETY ALERT – do not touch any of the exposed wires
  •  Step 2: Use a 3/8” to Tighten or loosen the larger spring (Rear Nut) to adjust the On & Off Pressures for the pump
  • Step 3: Use a 3/8” to Tighten or loosen the smaller spring (Front Nut) to adjust the Off Pressure only for the pump
  • Step 4: Check the adjusts made to the pressure switch – the Pressure Pump should Turn On at 30 PSI and Turn Off at 50 PSI
  • Step 5: After adjustments have been made at the Pressure Pump is set, re-install the pressure switch cover

If additional assistance is needed with your pressure switch adjustment contact ESD Waste2Water, Inc Service at 800-277-3279

Recent News

  • URG Training Conference 2026
  • 2026 CONEXPO-CON/AGG
  • How to Tackle Heavy Metal Contamination in the Mining Industry
  • 7 Sustainable Practices for Mining Operations
  • 4 Ways Your Business Can Be More Eco-Friendly

Categories

  • DIY Videos
  • Golf Courses
  • Heavy Equipment
  • Other
  • Pollution
  • Remediation
  • Trade Shows
  • Wash Water
Gallons of Recycled Water Gallons of Treated Water

Featuring our Solids Management System

We have created the ultimate in wash rack solids handling

Latest Blog

ESD Waste2Water is excited to announce that we’ll be exhibiting at the URG Training Confere...
Read More © 2017-2018, Waste2Water. All Rights Reserved. Privacy Policy

Request Information or a Quote

  • CommentsThis field is for validation purposes and should be left unchanged.
  • Your Name*
  • Company Name*
  • Email*
  • Phone*
  • Subject*
  • Your Message*
Close ESD Waste2Water

Tag » How To Adjust Pressure Switch