Caledonian, established in 1978, produces a wide range of copper, aluminium and fiber optic cables for communication, power and electronics in its primary plants in UK, Italy, Portugal , Turkey and Spain. To stay in front, we continually keep expanding our manufacturing capabilities in more low cost region such as China, Romania, Taiwan and Malaysia etc. This low-cost manufacturing facilities enables us provide execute a flexible, scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing and logistics services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market. Caledonian has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian has established an extensive network of design, manufacturing, and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.
Website http://www.caledonian-cables.co.uk/External link for Caledonian Cables
Industry Appliances, Electrical, and Electronics Manufacturing Company size 201-500 employees Headquarters London, England Type Privately Held Founded 1978 No more previous content400Hz Airport Cables 4-core With Control Wires
Network Access Control Software
FIREFLIX Fire Resistant Power & Control Cables是什么
Locations
- Primary
27 Old Gloucester Street
London, England, GB
Get directions -
64-66 Connaught Road Central
Hong Kong, Hong Kong, HK
Get directions -
Ocean Financial Centre
Singapore, Singapore, SG
Get directions -
Kagithane Ofispark Merkez Mah., Baglar
Istanbul, Istanbul, TR
Get directions -
Marchants Industrial Centre
Lewes, East Sussex, GB
Get directions -
Jingshi Road
Jinan, Shandong, CN
Get directions -
Espírito Santo 4410-420 Arcozelo
Porto, Porto, PT
Get directions -
South Sathorn Rd
Bangkok, Bangkok, TH
Get directions -
Nanjing Xi Lu
Shanghai, Shanghai, CN
Get directions
Employees at Caledonian Cables
-
airportcables chen
-
Sophia Jiang
-
rose chen
-
Alice Chuang
Updates
-
Caledonian Cables
331 followers
1w- Report this post
BS 5467 Armoured CPR approved Power Cables Three-core 600/1000 V cables with stranded copper conductors Application These BS 5467 Armoured CPR approved Power Cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The GSWA makes them suitable for use inside and outside buildings or for direct burial in the ground. Construction ConductorSolid Aluminum or Annealed Copper conductor, circular or shaped, Class 2 to BS EN60228InsulationXLPE (Cross-Linked Polyethylene) Type GP 8 conforming to BS 7655-1.3 or type GP 6 conforming to BS 7655-1.2.Colour Code1 Core : Brown or Blue 2 Cores: Brown, Blue 3 Cores: Brown, Black, Grey 4 Cores: Blue, Brown, Black, Grey 5 Cores: Green/Yellow, Blue, Brown, Black, Grey Above 5 Cores: White Cores with black numbersBeddingThe bedding shall consist of an extruded layer of polymeric material consistent with the operating temperature of the cable.ArmourSingle Core: AWA (Aluminum Wire Armour) Multi Core: GSWA (Galvanized Steel Wire Armour)Outer SheathExtruded PVC, type 9 specified in BS7655-4.2. Technical Information Voltage rating 600/1000V Temperature rating 0°C to +90°C Min. bending radius: 8 x overall diameter Flame retardant BS EN 60332-1-2 #BS5467 cable #Armoured cable #CPR approved cable #Power Cables #Flame retardant cable
Like Comment Share
-
Caledonian Cables
331 followers
2w- Report this post
BS 6346 CPR approved PVC Insulated Cables, 600/1000V Application These power and control cables are used for electricity supply in low voltage installation system. They are well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plant...). Construction Conductor Solid Aluminum or Copper conductor, round stranded or shaped, Class 2 to BS 6460, IEC 60228. Insulation PVC(Polyvinyl Chloride) type TI1 Colour Code 1 Core : Brown 2 Cores: Brown, Blue 3 Cores: Brown, Black, Grey 4 Cores: Blue, Brown, Black, Grey 5 Cores: Green-yellow, Blue, Brown, Black, Grey,Above 5 Cores: White Cores with black numbers Filler(optional) PVC or Polypropylene yarn Binder Tape(optional) Polyester (Mylar) tape Inner Sheath/ Bedding PVC (Polyvinyl Chloride) Armour Single Core: AWA (Aluminum WireArmour) Multi Core: SWA (Steel Wire or Tape Armour) Outer Sheath PVC(Polyvinyl Chloride), type TM1 Technical Information Voltage rating 600/1000V Temperature rating -20°C to +60°C Bending radius Single core: 10 x overall diameter Multicores: 8 x overall diameter Flame retardant IEC60332 part 1, BS4066 part 1 Three-core 600/1000V cables with solid aluminum conductors #BS6346 Cables #CPR approved cable #PVC Insulated cable #BS6346 standard cable
Like Comment Share -
Caledonian Cables
331 followers
3w- Report this post
BS 6724 Standards Armoured CPR approved Power Cables, 600/1000V Single-core with circular stranded copper conductor Application These BS6724 CPR approved cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The GSWA makes them suitable for use inside and outside buildings or for direct burial in the ground. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Construction ConductorSolid Aluminum or Annealed Copper conductor, circular or shaped, Class 2 to BS EN60228.InsulationXLPE (Cross-Linked Polyethylene) Type GP 8 conforming to BS 7655-1.3 or type GP 6 conforming to BS 7655-1.2.Colour Code1 Core : Brown or Blue 2 Cores: Brown, Blue 3 Cores: Brown, Black, Grey 4 Cores: Blue, Brown, Black, Grey 5 Cores: Green/Yellow, Blue, Brown, Black, Grey Above 5 Cores: White Cores with black numbersBeddingThe bedding shall consist of an extruded layer of polymeric material consistent with the operating temperature of the cable.ArmourSingle Core: AWA (Aluminum Wire Armour) Multi Core: GSWA (Galvanized Steel Wire Armour)Outer SheathLSOH (Low Smoke Zero Halogen),conforming to BS 7655-6.1.CPR ComplianceEca Technical Information Voltage rating 600/1000V Temperature rating 0°C to +90°C Min. bending radius: 8 x overall diameter Flame retardant BS EN 60332-1-2 ; BS EN 60332-3-24:2009 Halogen free BS EN 60754-1 Smoke density BS EN 61034-2 Single-core 600/1000 V cables with circular stranded copper conductor #BS 6724 Standards Cables #Armoured Power cable #CPR approved cable
Like Comment Share -
Caledonian Cables
331 followers
1mo- Report this post
CPR approved EN50288-7 Instrument Cables XLPE Insulated, LSZH Sheathed & Overall Screened Instrumentation Cables (Multicore) 18930597072 RE-2X(St)H 90°C/500V APPLICATION The LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas. Generally, the cables are used within industrial process manufacturing plants for communication, data and voice transmission signals and services.Also used for the interconnection of electrical equipment and instruments, the LSZH sheath can reduce toxic smoke and fume emission. STANDARDS Basic design to EN 50288-7 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional. VOLTAGE RATING 500V CABLE CONSTRUCTION Conductor: Annealed copper solid or plain copper stranded to IEC 60228 Class 2. Insulation: Extruded cross-linked XLPE compound, EN 50290. 2-29. Overall Screen: Aluminium/polyester tape with tinned copper drain wire, 0.5mm2 Outer Sheath: Halogen free flame retardant compound to EN 50290-2-27.UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. COLOUR CODE Insulation: Black numbered Outer Sheath: Black, blue for intrinsically safe systems PHYSICAL andTHERMAL PROPERTIES Temperature Range During Operation (Fixed State): -30°C – +90°C Temperature Range During Installation (Mobile State): -5°C – +50C Minimum Bending Radius: 7.5 X Overall Diameter ELECTRICAL ROPERTIES Conductor Area Sizemm20.50.751.01.31.52.5Insulation thickness (nominal)mm0.550.550.550.60.60.7Conductor resistance (20°C)Ω/km36.725.018.514.212.37.4Insulation resistance (20°C)MΩ.km(Min.)1000Mutual Capacitance (1 kHz)pF/m(Max.)250Capacitance unbalance(1 kHz)pF/500 m (Max.)500L / R (ratio) (max.)μH/Ω252525404060Operating voltageV500Test Voltage UrmsCore to CoreV2000Core to ScreenV2000
Like Comment Share
-
Caledonian Cables
331 followers
1mo- Report this post
CPR approved FIRETOX LSZH Flame Retardant Power Cables to BS EN 50525-3-31(Single Core) FTX100 05Z1-U/R/K (CU/LSZH 300/500V Class 1/2/5) HAR Code: H05Z1-U/R/K Applications BS EN 50525-3-31 300/500V LSZH Insulated, Non-sheathed Power Cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals and high-rise buildings.. Standard Basic design adapted to BS EN 50525-3-31 FIRE PERFORMANCE Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24Halogen FreeIEC 60754-1; EN 50267-2-1No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2Minimum Smoke EmissionIEC 61034-2; EN 61034-2 Voltage Rating 300/500V Construction ConductorCopper conductor according to BS EN 60228 class 1/2/5.InsulationThermoplastic compound of type TI 7 to EN 50363-7.Insulation OptionUV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Colour Code Black, Blue, Brown, Grey, Orange, Pink, Red, Turquoise, Violet, White, Green and Yellow. Bi-colours of any combination of the above mono-colours are permitted. PHYSICAL AND THERMAL PROPERTIES Maximum temperature range during operation:70°CMaximum short circuit temperature (5 Seconds):160°CMinimum bending radius:4 x Overall Diameter CONSTRUCTION PARAMETERS ConductorFTX100 05Z1-U/R/KNo. of Cores × Cross-sectional AreaConductor ClassNominal Insulation ThicknessMin. Overall DiameterMax. Overall DiameterApprox. WeightNo.×mm2 mmmmmmkg/km1×0.5010.61.92.39.41×0.7510.62.12.512.21×1.010.62.22.715.41×0.5020.62.02.410.11×0.7520.62.22.613.01×1.020.62.32.816.81×0.5050.62.12.59.91×0.7550.62.22.713.31×1.050.62.42.816.2Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information.
Like Comment Share -
Caledonian Cables
331 followers
2mo- Report this post
We are thrilled to announce the successful completion of the cable supply project for Malé Velana International Airport in the Maldives! We delivered a full suite of medium & low voltage power cables, control cables, and data transmission cables. Thanks to our outstanding performance in this project, we have officially secured a spot on the Maldives' national supplier shortlist. Looking ahead, we stand ready to support any infrastructure projects in the Maldives and surrounding regions. Leveraging our benchmark project experience, reliable products, and comprehensive services, we are committed to safeguarding the success of your engineering ventures. #Maldives Infrastructure Projects #Belt and Road Overseas Engineering #Cable Solutions #Caledonian cable
Like Comment Share -
Caledonian Cables
331 followers
6mo- Report this post
EN50362 STANDARD The EN 50362 standard, as a test method for fire resistance of large unprotected power supply and control cables used in emergency circuits, has a clear and critical position in the fire resistance performance evaluation of emergency circuit cables. 1. Scope of application of the standard The EN 50362 standard mainly applies to power cables and control cables with a rated voltage ≤ 0.6/1 kV, and these cables belong to large unprotected cables with an outer diameter>20 mm. This means that in emergency circuits, cables responsible for ensuring the power supply of firefighting equipment in the fire protection system, cables providing lighting for evacuation routes in the emergency lighting system, and cables related to the power supply of escape routes, as long as they meet the above voltage and outer diameter requirements, their fire resistance testing must comply with this standard. For cables with an outer diameter ≤ 20 mm, they need to be tested according to EN 50200. Through this clear division, it is ensured that cables of different specifications can receive appropriate fire resistance evaluations. 2.Testing requirements During the testing process, the setting of various conditions is extremely strict to fully verify the fire resistance of the cable in extreme environments. Flame conditions: The flame temperature during testing needs to be controlled at 842 ° C, with an actual allowable fluctuation range of 830 ° C+40/0C. This high temperature simulates the extreme high temperature environment that cables may face during a fire, testing the stability of cables under continuous high-temperature burning. Mechanical impact: At the same time as the flame burns the cable, mechanical impact should be applied to it, and the impact interval is strictly defined as 5 minutes. This synchronous mechanical impact simulates the external forces that may occur on cables during a fire, such as building vibrations and object falls, and comprehensively tests the cable's tolerance. Testing time: The entire testing process takes 120 minutes, and the prolonged testing ensures that the cable can maintain a certain level of performance during the fire, buying valuable time for the normal operation of the emergency circuit. 3. Comparison between EN 50362 standard and EN50200 fire protection standard Standard EN 50362 EN 50200 Applicable cable diameter >20 mm ≤20 mm Flame temperature 842°C (830°C±40) 842°C (830°C±40) Mechanical impact 5min+/-10s intervals 5min+/-10s intervals water spray test Not required Optional (Additional Options) Test time 120 minutes 30/60/90/120 minutes #EN50362 STANDARD #Fire-resistant cable standard
1 Comment Like Comment Share
-
Caledonian Cables
331 followers
7mo- Report this post
FAA L-824 Type C 600V Airport Cables Airport Cables Applications These Airport Cables are designed for use in airport lighting and control circuits, suitable for installation in ducts, conduit and direct burial. » Airport Cables Standards FAA L-824 Type C ICEA S-95-658/NEWA WC71 » Airport Cables Construction Conductor: Stranded bare copper to ASTM B. Insulation: XLPE. Sheath (for multiconductor cables only): PVC. » Airport Cables Technical Data Rated Voltage Uo/U (Um) 600V Maximum Conductor Temperature 90℃ Short Circuit Temperature 250℃ Operating Temperatures -40℃~+90℃ Minimum Bending Radius 5×OD #FAA L-824 Type C 600V Airport Cables #FAA L-824 Type C Cables #600V Airport Cables #Airport Cables
1 Comment Like Comment Share
-
Caledonian Cables
331 followers
7mo- Report this post
RG7H1R for Airport Lighting Cables Applications These cables are used as airfield lighting equipment primary cables for the series circuit connecting the Constant Current Regulators and the isolating transformers, and between the isolating transformers. Standards ENV 50213 Construction Conductor: Compact stranded bare copper conductor. Inner Semi-Conductor: Extruded semi-conducting compound. Insulation: High module rubber compound, G7 type. Outer Semi-Conductor: Extruded semi-conducting compound. Shield: Bare copper tapes. Sheath: PVC. Technical Data Rated Voltage Uo/U (Um) 3.6/6kV Maximum Conductor Temperature 90℃ Short Circuit Temperature 250℃ Operating Temperatures 0℃~+90℃ Minimum Bending Radius 15×OD Flame Retardant Yes #RG7H1R Airport Cables #Airport Lighting Cables #Airport Cables
1 Comment Like Comment Share
-
Caledonian Cables
331 followers
8mo Edited- Report this post
#EN50288-7 Standard Fire resistant Instrumentation Cables #Fire resistant Instrumentation Cables #Instrumentation Cables Fire Resistant Copper Braid Screened, Armoured Instrumentation Cables(Multipair) National Hotline 18930597072 RE-2X(C)HSWAH ... CI APPLICATION The armoured LSZH sheathed cables are generally used when the risk of mechanical damage is increased. The galvanized steel wire armour provides excellent protection. Generally, the cables are used within industrial process manufacturing plants for communication, data and voice transmission signals and services. Also used for the interconnection of electrical equipment and instruments, the LSZH sheath can reduce toxic smoke and fume emission.. STANDARDS Basic design to BS EN 50288-7 (formerly BS 5308) FIRE PERFORMANCE Circuit Integrity IEC 60331-1:IEC 60331-2:IEC 60331-21:BS 6387 CWZ(Optiona); BS EN 50200(PH30/PH60/PH 120) Flame Retardance (Single Vertical Wire or cable test) IEC 60332-1-2; EN 60332-1-2Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24Halogen FreeIEC 60754-1; EN 50267-2-1 No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2Minimum Smoke EmissionIEC 61034-2; EN 61034-2 VOLTAGE RATING 300, 500V CABLE CONSTRUCTION Conductor Plain or metal coated copper wire, solid, stranded or fiexible according to lEC 60228 class 1, 2and class 5. Fire Barrier Mica glass tape. Insulation、 Extruded XLPE compound according to EN50290-2-29. Pairs Two insulated conductors uniformly twisted together with a lay not exceeding 100mm (s1.5mm) or150mm (for 2.5mm). Binder Tape PETP transparent tape.Overall ScreenCopper braid screen.Inner SheathThermoplastic LSZH compound. Armouring Galvanised steel wire armour.Outer SheathHalogen free flame retardant compound to EN 50290-2-27. COLOUR CODE Insulation Colour Colours and/or additional ring markings and/or symbols achieved by the use of colouredinsulation or by a coloured surface using extrusion, printing or painting.Outer SheathBlack. Other colours can be offered upon request. PHYSICAL AND THERMAL PROPERTIES Temperature range during operation -30°C - +90°C Temperature range fixed installation -5°C - +50°C Maximum short circuit temperature (5 Seconds) 250°C Minimum bending radius 10 × Overall Diameter https://lnkd.in/gSgZ72CU
1 Comment Like Comment Share
Join now to see what you are missing
- Find people you know at Caledonian Cables
- Browse recommended jobs for you
- View all updates, news, and articles
Similar pages
-
FS Cables
Appliances, Electrical, and Electronics Manufacturing
Luton, Bedfordshire
-
Cleveland Cable Company
Appliances, Electrical, and Electronics Manufacturing
-
Southwire Company
Appliances, Electrical, and Electronics Manufacturing
Carrollton, GA
-
DOEFLEX LIMITED
Plastics Manufacturing
-
C&L Covers
Packaging & Containers
Wallasey , Wirral
-
plus1hp
Computer Games
Firestone, CO
-
WKH Group Limited
Plastics Manufacturing
-
Arc Kablo
Appliances, Electrical, and Electronics Manufacturing
SİNOP, BOYABAT
-
New Age Industrial Sales
Appliances, Electrical, and Electronics Manufacturing
Denver, CO
-
ELETTRONICA CONDUTTORI S.R.L.
TORINO, To
Agree & Join LinkedIn
By clicking Continue to join or sign in, you agree to LinkedIn’s User Agreement, Privacy Policy, and Cookie Policy.
Sign in to see who you already know at Caledonian Cables
Email or phone Password Show Forgot password? Sign in Sign in with Emailor
New to LinkedIn? Join now
By clicking Continue to join or sign in, you agree to LinkedIn’s User Agreement, Privacy Policy, and Cookie Policy.
LinkedIn is better on the app
Don’t have the app? Get it in the Microsoft Store.
Open the appTừ khóa » Xp C 32-321
-
NF-C 32-321 Cable - Eland Cables
-
Standard XP C32-321 - Afnor EDITIONS
-
[PDF] BARRYNAX U-1000 R2V
-
French Standard Industrial Cables U-1000 R2V
-
Standard Cables - Nexans
-
U-1000 R2V 7G1.5 C50m - Nexans
-
U-1000 R2V - XLPE Insulated, Copper Conductor, PVC Outer Sheath ...
-
Nouvelles Normes XP C - CA2E
-
[PDF] Certification Rules NF 003_ Rev B Draft English 24032016 FINAL
-
U-1000 AR2V - Batt Cables
-
Multicore Cable RPC EN 50575 PROFIPLAST U1000 R02V | OMERIN
-
[PDF] U-1000 R2V - Borsan Kablo
-
[PDF] 4x U-1000 AR2V - Alcobre