Conversion Of Nm3/hr Air To Actual Vapour Flow
Có thể bạn quan tâm
Jump to content
- Sign In
- Create Account
Featured Articles
Check out the latest featured articles.
File Library
Check out the latest downloads available in the File Library.
New Article
Product Viscosity vs. Shear
Featured File
Vertical Tank Selection
New Blog Entry
Low Flow in Pipes- posted in Ankur's blog
Conversion Of Nm3/hr Air To Actual Vapour Flow Started by kirangparihar, Jun 22 2006 04:08 PM This topic has been archived. This means that you cannot reply to this topic. 6 replies to this topic Share this topic: | More#1 kirangparihar
kirangparihar- Members
- 13 posts
Junior Member
Posted 22 June 2006 - 04:08 PM
Hi all,API 2000 gives the relieving rate required in terms of Nm3/hr of air. I am a bit confused over the equations to be used for converting this Nm3/hr of air to the actual vapour flowrate. The options given are:1. Gas Law equation PV = ZnRT. Equating the terms for Air & gas at required temp & pressure & solving for the flow rate2. W2 = W1 x SQRT((Z1 x T1 x M2) / (M1 x Z2 x T2)) W2, Mass Flow rate of Air (Kg / hr) W1, Mass Flow rate of Gas (Kg / hr) Z1, Compressibility factor for Gas T1, Temperature of Gas in °K M1, Molecular Weight of Gas (Kg / Kmole) M2, Molecular Weight of Air (Kg / Kmole) Z2, Compressibility Factor for air T2 , Temperature of air in °K 3. As mentioned in the link below http://www.enardo.co...s_equations.htmOfcourse all three gives different results. It would be quite helpful if anybody can explain me which equation to be used & more importantly WHY.Thanks in advance#2 djack77494
djack77494- ChE Plus Subscriber
- 1,282 posts
Gold Member
Posted 23 June 2006 - 04:21 PM
kirangparihar,I'm not quite sure what you're asking. Please try to better explain what your problem is, as I don't think that I can address it properly without more help from you.I believe you're asking how to convert back and forth between Nm3/hr of air and Nm3/hr of a vapor stream that could be vented from a tank. Equations 1 & 2 are essentially the same, and are probably not enough to get you where you want to go. The Enardo equations are also very basic, but aren't going to get you any closer to what you need to know. I suggest that you start with understanding the characteristics of the device you are dealing with. Let's say you're interested in a relieving scenario where you want to vent process vapors from an atmospheric tank. (This is what I think you're interested in.) So you have somehow determined the flowrate of your vapor stream that will pass through a PSV to atmosphere. Now you look at the vendor's literature and discover that their devices are rated in Nm3/hr of air. Is this the situation you are facing? To delve into this further, I need your confirmation that I'm moving in the correct direction. Is this what you seek? If not, please correct my misunderstanding of your problem.Thanks,Doug#3 kirangparihar
kirangparihar- Members
- 13 posts
Junior Member
Posted 24 June 2006 - 10:31 AM
Hi DougFirst of all, thanks for your reply. The problem that I am facing is simple and will I try to explain although it may seem that I should have started the topic in Students Forum indeed !!! I have to size a Vapour Recovery Unit for the tank farm area. I have calculated the vapour loading for the VRU from API 2000 & essentially it gives the results in Nm3/hr of air (or SCFH of air).When I started converting back this flow rate to Kg/hr (mass flow rate), I used the Enardo equations for the same wherein the term "Volumetric Flow is inversely proportional to the square root of the Molecular Weight (MW) of the vapor". This thing raised the eyebrow of the Engineers here and asked me why can't we use simple PV = nRT wherein no square root term comes into picture!!!. I had a vague answer for that.I tried to dervive the term sqrt (M2/M1) by using the continuity equation Q = A x v wherein v (velocity) is replaced using the equation Del. P = v^2 / 2g. From here I got the term "under root of Del.P" which again can be replaced by P = nRT/V. Somewhere I got close to term sqrt (M2/M1).Hence Proved!!!. But I got no takers for my derivation since it contains other terms too & also I am not too confident.Also if we simply look API 520 equations We have flow rate proprotional Sqrt (Temp, & 1/M.W). Now here the problem is that the along with Molecular weight, temperature is also a term in Sqrt. I got a lot of confusion!!!.In simple words, for converting Nm3/hr of Air to Actual m3/hr (or Kg/hr), which of the 3 equations should I useThanks in advanceKiran Parihar#4 mbeychok
mbeychok- ChE Plus Subscriber
- 364 posts
Gold Member
Posted 26 June 2006 - 02:06 AM
Kiran Parihar:You are making some simple conversions much harder than they are by looking at too many confusing references. So let's forget all the equations you've looked at and start from fundamentals!! Converting Nm3/h to actual m3/hr:First of all, you must find out what reference temperature (Tr) and reference pressure (Pr) were used for defining the Nm3/h that you obtained. A Nm3 is usually (but not always) defined as being at 273.15 °K and 101.325 kPa (kiloPascals). Since other reference conditions may have been used, you should find out exactly what reference temperature and pressure was used to define your Nm3/h ... I want to stress that most strongly.Now, using the universal gas law twice:(1) ... (Pa)(Va) = (Za)(n)(R')(Ta)(2) ... (Pr)(Vr) = (Zr)(n)(R')(Tr)Dividing equation (1) by equation (2), we get:Va = (Vr)(Za/Zr)(Ta/Tr)(Pr/Pa)where: Va = actual m3/hrVr = Nm3/hZa = compressibility factor at Ta and Pa, dimensionlessZr = compressibility factor at Tr and Pr, dimensionlessTa = the absolute temperature at which you want the actual m3/h, in °KPa = the absolute pressure at which you want the actual m3/h, in kPa (i.e., kiloPascals)Tr = the absolute reference temperature that applies to your Nm3/h, in °KPr = the absolute reference pressure that applies to your Nm3/h, in kPa (i.e., kiloPascals) Unless your actual condition pressure (Pa) is quite high or you need some very high accuracy, in most cases you can ignore using the compressibility factors.Converting either Nm3/h or actual m3/h to kg/h:Again, start with the universal gas law:(3) ... (P)(V) = (Z)(n)(R')(T) ..... and since n = w/M, we get:(4) ... w = (M)(P)(V) / [(Z)(R')(T)]where:w = kg/hM = molecular weight of the gasT = absolute temperature, in °KP = absolute pressure, in kPa (i.e., kiloPascals)R' = the universal gas law constant of 8.3145Z = the compressibility, dimensionless Equation (4) could be used to get kg/h based on using either the Z, P and T of your actual m3/h or the reference Z, P and T of your Nm3/h. Either way should give the same answer.I am assuming that up to this point, everything is based on air (M = 28.96). So finally, to convert to your actual gas:kg/h of gas = (kg/h of air)(M of gas) / (M of air)To clear up confusion about square root term:If your Nm3/h of air was obtained from a flow meter of some type that works by measuring a ΔP across an orifice or some other device and you want to re-calibrate the meter to use a different set of reference temperature and pressure, then the square root term comes into play. But, in this case, it seems to me that you are not trying to re-calibrate a meter. You are simply tring to convert the Nm3/h of air (that you got from a meter or some other way) to kg/h of your actual gas. In that case, the above equations are all you need!#5 djack77494
djack77494- ChE Plus Subscriber
- 1,282 posts
Gold Member
Posted 26 June 2006 - 12:55 PM
Kiran:There's not much I can add to Milton's excellent and comprehensive reply to your question. In fact, your question alerted me to my own ignorance of the principles involved in venting devices. Though I'm finding this question a bit difficult to express, I am curious if a conservation vent, PSV, etc. would be considered to be mass or a volumetric devices. I know that for gases conservation vent and PSV's and rupture disks, etc. tend to be rated in Nm3 or SCF per unit of time. If they are volumetric devices, then if the molecular weight changed, they would still be capable of passing the same Nm3 or SCF as before (constant volume = constant moles). If they are mass flow devices, then if the molecular weight were to increase, then the Nm3 or SCF rating would have to decrease to keep the kg/hr or lb/hr constant (but moles vary). Could anyone explain how these devices operate?Thanks,Doug#6
- guestGuests
- 0 posts
Posted 03 January 2008 - 12:58 PM
Dear Kirangparihar,regarding your query on the 22 of Jun 2006 4:08 p.m.I know that my reply comes late but I saw the discussion only now. My response is:-------------------------------------------------------------------Your objective I believe is to calculate the equivalent flow of your substance that will give you the same relief valve size as the flow of air calculated by API-2000. First of all, if I were you I would send the equivalent flow of air to the valve vendor and the supplier then will size the valve accordingly. If you insist converting the mass flow of air to the equivalent mass flow of the substance that gives you the same orifice size then I would go with your approach number 2.Note equation 4A and 4B in API2000. For the same orifice area we should have: A = Wair*SQRT(Mair*Tair*Zair) = Wreal*SQRT(Mreal*Treal*Zreal).Wair in Nm3/hrWreal in Nm3/hrIf you convert the Nm3/hr to kg/hr you will getSo W_air*SQRT(Mreal*Tair*Zair) = W_real*SQRT(Mair*Treal*Zreal)which is your option 2.W_air in kg/hrW_real in kg/hrNow API2000 assumes that the air is at 15degC. You can prove that by deriving equations (1B) and (1A) in the same standard. The compressibility of air is 1 and we assume here that the isentropic exponent in equations (4A) and (4B) is the same for air and for the vapour you are looking at.I have crossed checked the result with:1. Vendor data (Shand & Jurs)2. Equation (1A) and (1B) of the same standard that basically converts the vapour release to air flow at 15degC using the same formula.mbeychock to my understanding assumes that the same molar flow of air and gas will give the same relief valve orifice size, hence he is using the equation:kg/hgas = (kg/hr air) *(M of gas) / (M of air).This is not correct according to API200 eq. (4A) and (4B) that dictate that the orifice area is proportional to the molar flow and to the square root of temperature and molecular weight....----------------------------------------------------------------------------------------------------------------For all the above I followed standards rather than judgement and intuition.Hope it helps for any more info please communicate via e-mial I can send you the derivations and the vendor data.#7 CMA010
CMA010- Members
- 92 posts
Gold Member
Posted 05 January 2008 - 06:46 AM
Also late and maybe adding to the confusion. A large chemical company says the following in their guidelines for pressure relief:An actual volumetric flow rate of gas or vapour at tank conditions can be converted to the equivalent air flow rate at reference conditions by multiplying the actual volumetric flow rate by: SQRT(rho_A/rho_R) Where:rho_A: Vapour density at tank conditionsrho_R: Air density at reference conditionsUsing this method gives slightly different values compared to the Enardo method but can give massive differences compared to the gas law method (depending on molecular weight of the gas).Similar Topics
Relieving Flow Rate In Terms Of Air EquivalentStarted by Guest_go-fish_* , 21 Nov 2024 |
|
|
Constant Volume Vs Constant Mass Flow Of Centrifugal CompressorsStarted by Guest_panoska_* , 18 Nov 2024 |
|
|
Venturi Scrubber- Liquid Flow RateStarted by Guest_Chemeng40_* , 09 Nov 2024 |
|
|
Centrifugal Compressors (Actual Vs Polytropic Head)Started by Guest_panoska_* , 25 Oct 2024 |
|
|
Software For Calculating Flow Through A PipeStarted by Guest_Deep24_* , 07 May 2018 |
|
|
- Mark Community Read
- Help
Community Forum Software by IP.Board
Sign In
- Need an account? Register now!
- Username or email:
- Forum Password I've forgotten my password
- Remember me This is not recommended for shared computers
- Privacy Policy
Từ khóa » Volumetric Flow Rate Nm3/hr
-
FAQs | Frequently Asked Questions - Classic Filters
-
Volume Flow Or Mass Flow Rates Normal Flow Nm3 Nm3 / H M3 M3 / H
-
Calculation Of NM3/hr And SM3/hr Gas Flow - EnggCyclopedia
-
Normal Cubic Metres Per Hour (Nm3/h) | Oil And Gas Drilling Glossary
-
Use Of Nm3/hr Unit - Chemical Process Engineering - Eng-Tips
-
Nm3/hr To Actual M3/hr - Airpack
-
Different Between Nm3/h = M3/h ? - OnlineConversion Forums
-
How Do You Convert Nm3 Hr To Kg Hr For Air?
-
Difference Between Actual, Standard And Normal Flows
-
NM3/hr And SM3/hr Gas Flow Calculation - Engineers Community
-
Nm3/Hr To M3/Hr FAD Calculations - LinkedIn
-
Đơn Vị Nm3/H Là Gì - Volumetric Flow Rate
-
Gas Flow Calculator - Xchanger
-
Nm3/hr To M3/hr . - CR4 Discussion Thread - GlobalSpec