Nm3/Hr To M3/Hr FAD Calculations - LinkedIn

Agree & Join LinkedIn

By clicking Continue to join or sign in, you agree to LinkedIn’s User Agreement, Privacy Policy, and Cookie Policy.

Sign in to view more content

Create your free account or sign in to continue your search

Sign in

Welcome back

Email or phone Password Show Forgot password? Sign in

or

By clicking Continue to join or sign in, you agree to LinkedIn’s User Agreement, Privacy Policy, and Cookie Policy.

New to LinkedIn? Join now

or

New to LinkedIn? Join now

By clicking Continue to join or sign in, you agree to LinkedIn’s User Agreement, Privacy Policy, and Cookie Policy.

LinkedIn

LinkedIn is better on the app

Don’t have the app? Get it in the Microsoft Store.

Open the app Skip to main content
Nm3/Hr to m3/Hr FAD Calculations

A BRIEF ON CALCULATIONS AND UNDERSTANDING OF CONCEPT

Before proceeding ahead let us understand the concept of Free Air Delivery and its different measurement units

Free air delivery is the volume flow rate of gas compressed and delivered at the standard discharge point, referred to the atmospheric conditions of the site, not affected by the compressor. F.A.D. can be expressed in l/s, m3/min or cfm.

Most of the compressor manufacturers uses by ISO 1217 annex C (downstream of the aftercooler, check valve and water separators) to measure compressor flow and it is widely accepted throughout the world.

WHAT IS ISO 1217 ANNEX C ?

Compressed Air Flow is nothing but the volume flow rate of Air with reference to ambient conditions or Normal Conditions or Standard conditions and so on

For ISO 1217, the manufacturers refer to below mentioned reference conditions to calculate FAD

Ambient temp. = 20ºC

Bar pressure = 1 bar

Relative Humidity = 0%

There are other measurement types used by manufacturers mostly from oil & gas industry like Normal Conditions, Standard Conditions or Inlet conditions

WHAT ARE NORMAL CONDITIONS ?

Volume flow rate of gas compressed and delivered at the standard discharge point, but with reference to Standard/ Normal conditions for temperature, pressure and inlet gas composition (humidity).

Temp. = 0ºC

Bar pressure = 1.013 bar

Relative humidity = 0%

CONVERSION – NM3/HR TO M3/HR

We will use universal gas equation to convert from Nm3/Hr to M3/Hr

PsVs/Ts = PnVn/Tn

Ps- Ambient Pr at site

Ts-Max Ambient temp at site

Rh- Avg Relative Humidity

Vs – Flow at Site – To be calculated

Normal Conditions:

Pn- Pr at normal conditions

Tn-Temp at Normal conditions

Vn – Flow ate Normal Conditions

WE WILL USE BELOW MENTIONED FORMULA TO CALCULATE SITE PRESSURE

• Ps = Pa – RH x Pvs to calculate dry air pressure at site

Ps- Ambient Pr at site – ?

Pvs – Vapour Pressure - 0.1234 bar @ 50 C

Rh- Avg Relative Humidity – 43%

Pa – Ambient Pressure – 1,013 Bar

Hence Ps = 1.013 – 0.43 X 0.1234

Ps = 0.959 Bar

CONVERSION CALCULATIONS

Ps- Ambient Pr at site – 0.959 Bar

Ts-Max Ambient temp at site – 50 °C (considering Oman conditions)

Rh- Avg Relative Humidity – 43%

Vs – Flow at Site – To be calculated

Normal Conditions:

Pn- Pr at normal conditions – 1.013 bar

Tn-Temp at Normal conditions – 0 °C

Vn – Flow ate Normal Conditions – 154 Nm3/Hr ( Given by Customer)

PsVs/Ts = PnVn/Tn

(0.959XVs)/323 = (1.013X154)/273

Vs = 192.5 Mr/Hr

Hence we concluded that the correct flow to be taken into consideration for sizing compressors will be 192.5 Mr/Hr

Like Like Celebrate Support Love Insightful Funny Comment
  • Copy
  • LinkedIn
  • Facebook
  • Twitter
Share 7 Comments Aritra Kumar Biswas Aritra Kumar Biswas 2y
  • Report this comment

It might be good idea to consider the moisture mass as well in the calculation before defining the capacity. It will be significant!!

Like Reply 1 Reaction Consultant Mian Usman / CES Group International Consultant Mian Usman / CES Group International

Power Plant EPC Services (5 - 50 MW) + Boiler & Turbine Overhaul (Repair & Maintenance) + Spare Parts & Consumables

2y
  • Report this comment

Excellent Work !

Like Reply 1 Reaction Geron Farro Geron Farro

Senior Mechanical Engineer at Archetype Philippines Inc.

4y
  • Report this comment

Hi Mr. Prashant Bawane, i'm just wondering if the above information regarding properties of Air is correct at normal condition (NTP)?...hoping for your further clarification...;)

Like Reply 1 Reaction Ratheesh manhacheri Ratheesh manhacheri

Lead Rotating Equipment Engineer at Fotune Engineering and Energy Services, Dubai

4y
  • Report this comment

so 192.5 Mr/Hr is the FAD value? why pressure is not associated with it? Suppose the customer specifies 154 Nm3/Hr at 9 bar discharge pressure. So the compressor vendor will use 192.5 m3/hr at 9 bar for model selection?

Like Reply 1 Reaction 2 Reactions AIR TECHNIQUE COMPRESSEUR POWERAIR DU GROUPE ATLAS COPCO) AIR TECHNIQUE COMPRESSEUR POWERAIR DU GROUPE ATLAS COPCO)

Vente et Réparation Compresseur air; Sécheur air; Filtres; Huile ROTAIR/Générateurs Oxygène/Azote/Pompe Vide. Location/Maintenance/Réparation. Fournitures Industrielles

4y
  • Report this comment

Dear Prashant thanks for that information. I have a question a customer gave me machines data 22600 NL/mn and pressure of 7 bars. He and asked me which compressor for that need. Firstly, I have to calculate the Air flow rate in L/S taking into account pressure 7 bars? I see in above formula the working pressure is not included? Thanks to help me

Like Reply 1 Reaction See more comments

To view or add a comment, sign in

No more previous content
  • HOW TO GENERATE ENQUIRIES

    HOW TO GENERATE ENQUIRIES

    Mar 22, 2021

  • Air Compressor - Industrial Applications

    Air Compressor - Industrial Applications

    May 13, 2020

  • COMPRESSOR SALES TRICKS - PART 1

    COMPRESSOR SALES TRICKS - PART 1

    Jul 10, 2018

  • How to measure Air Compressor FAD using Receiver Pressure Volume Calculations ?

    How to measure Air Compressor FAD using Receiver Pressure Volume Calculations ?

    Feb 4, 2018

No more next content See all

Insights from the community

  • Hydraulic Systems What are the key factors to consider when sizing a hydraulic reservoir for your power unit?
  • Solar Thermal How do you troubleshoot and repair problems with the pump and the expansion vessel?
  • Materials Science What is the best way to analyze and interpret thermal conductivity test results?
  • Hydraulic Systems What are the best ways to cool down a hydraulic power unit in hot weather?
  • Industrial Engineering What causes air compressor oil contamination?
  • Chemical Engineering How can you select materials for chemical processing that resist fire and explosions?
  • Power Management What are the trade-offs and benefits of different cooling methods for power components?
  • Mechanical Engineering How can you use thermodynamic properties to select the right diagrams?
  • Water Engineering How do you select the optimal pipe size and material for a water distribution system?
Show more Show less

Others also viewed

  • Water to steam: How does the pressure make a difference? [Explanation using steam table and TS diagram]

    Nikhilesh Mukherjee 2y
  • Temperature cross in shell and tube heat exchanger: How and why?

    Nikhilesh Mukherjee 1y
  • Heat exchanger: Logarithmic temperature average

    Nikhilesh Mukherjee 1y
  • Bolier Carryover

    Nikhilesh Mukherjee 10mo
  • Pressure drop vs Enthalpy of vaporization

    Nikhilesh Mukherjee 1y
  • 𝐆as 𝐓urbine 𝐂𝐎2 𝐝𝐢𝐬𝐜𝐡𝐚𝐫𝐠𝐞 𝐭𝐞𝐬𝐭

    Ahmed Hamdy Abd Elrahman 1y
  • Pressure & Heat - Part 4 - Efficient Compression

    Conor Eaton-Smith 8mo
  • The Generation of Compressed Air

    Mostafa Mohamed Sayed 5y
  • What is barometric pressure?

    ES Systems 1y
Show more Show less

Explore topics

  • Sales
  • Marketing
  • IT Services
  • Business Administration
  • HR Management
  • Engineering
  • Soft Skills
  • See All

Từ khóa » Volumetric Flow Rate Nm3/hr