Crowcon Xgard Type 1 Carbon Monoxide - Safety Gear Store

Có thể bạn quan tâm

Crowcon Xgard Type 1 Carbon Monoxide

Require Install, Commissioning, Calibration or Servicing?

Safety Gear Store are able to install, commission and service your fixed gas detection system. We offer a professional service from fully trained, certified and manufacturer approved engineers, we are also one of the only suppliers with engineers that carry spares in their vehicles to ensure a quick and efficient service that will enable you to continue using your facility.For more information on what we offer please visit one of the below pages:

Fixed Gas Detection System Install and Commissioning

Fixed Gas Detection System Calibration and Servicing

XG1-N1-01-AM Carbon monoxide 0-1000ppm CO

 

The Xgard range is a comprehensive selection of fixed point gas detectors that meet the diverse requirements for gas detection in industries throughout the world. This includes many water treatment, oil and gas, power, research facility and manufacturing installations.

Overview:

Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX, UL and GOST-R.

Low cost of ownership

  • Designed for easy installation and maintenance – keeps costs down
  • Three junction box options – designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in
  • Many spare parts are common to all Xgard models – keeps spares holding requirements to a minimum

Flexible installation options

  • Designed for either wall or ceiling mounting – no need for additional brackets
  • Can accommodate M20, 1/2″ NPT or 3/4″ NPT cable glands – suits all site requirements
  • High temperature models are available for hot environments (up to 150oc)
  • Accessories are available for duct mounting and sampling applications as well as remote gassing – simple sensor checking

Wide range of sensors

  • Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens
  • Electrochemical sensors are used to detect a vast range of toxic gases and oxygen
  • Thermal conductivity sensors are available to monitor % volume concentrations of gases

Rugged and reliable

  • Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance – designed to operate even in the harshest environments
  • Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
  • All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3)

Specifications:

  Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs) 1.5 kg (3.3lbs) Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs)
Enclosure material ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S Aluminium or 316 Stainless Steel Aluminium Aluminium or 316 Stainless Steel
Ingress protection IP65 IP54 IP65
Cable entries 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations 0.5 to 2.5mm2
Sensor type Electrochemical Catalytic bead 316 S/S sensor housing with catalytic beads Catalytic bead Thermal conductivity
Operating temperature -40 to +50 °C(-40 to 122 °F)(sensor dependant) -20 to +50°C (-4 to 122°F) -40 to +80°C(-40 to 176°F) -20 to +150°C (-4 to 302°F) -40 to +55°C (-40 to 131°F) +10 to +55°C (50 to 301°F)
Humidity 10 to 95% RH non-condensing 0-99% RH non-condensing 0-90% RH
Repeatability Zero drift <2% FSD (Typical)<2% FSD per Month (Typical)
Response time T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) T90 <15s (Typical)
Operating voltage 8-30V dc 2.0V dc +/- 0.1V (Typical) 10-30V dc
Power requirements 24mA maximum 300mA (Typical) 50mA at 24V dc 1.2W
Electrical output 2- wire 4-20mA (current sink) 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 3- wire 4-20mA (current sink or source)
Approvals ATEX: II 1 GExia IIC T4 Ga(Tamb -40 to +55°C)UL/cUL: Class I, Div. 1Groups A, B, C, DIECExGOST-R ATEX: II 2GDExd IIC T6 Gb (Tamb -40 to +50°C)UL: Class I, Div. 1Groups B, C, DIECExGOST-R ATEX: II 2 GDExd IIC T4 Gb(Tamb -40 to +80°C)Exd IIC T6 Gb (Tamb -40 to +50°C)Ex tb IIICT180°C DbUL: Class I, Div. 1Groups B, C, DIECExGOST-R ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C)Exd IIC T4 Gb (Tamb -40 to +80°C)Ex tb IIICT180°C DbUL: Class I, Div. 1Groups B, C, DIECExGOST-R
EMC compliance EN 50270       FCC Part 15    ICES- 003

*3/4 ” cable entry only available on aluminium juntion boxes.

Sensors available are:

XG1-N1-01-FM

Acetylene 0-100%LEL

 

XG1-N1-01-SJ

Ammonia 0-1000ppm NH3 (-20C min)

 

XG1-N1-01-SG

Ammonia 0-100ppm NH3 (-20C min)

 

XG1-N1-01-AR

Ammonia 0-100ppm NH3 (-40C min)

 

XG1-N1-01-FQ

Ammonia 0-25%LEL NH3

 

XG1-N1-01-SH

Ammonia 0-250ppm NH3 (-20C min)

 

XG1-N1-01-SI

Ammonia 0-500ppm NH3 (-20C min)

 

XG1-N1-01-SF

Ammonia 0-50ppm NH3 (-20C min)

 

XG1-N1-01-AS

Arsine 0-1ppm AsH3

 

XG1-N1-01-AT

Bromine 0-3ppm  Br2

 

XG1-N1-01-BL

Butane 0-100% LEL C4H10(IR)

 

XG1-N1-01-FG

Butane 0-100%LEL

 

XG1-N1-01-KG

Butene 0-100% LEL C4H8(IR)

 

XG1-N1-01-CY

Carbon dioxide 0-2% volume CO2(IR)

 

XG1-N1-01-HG

Carbon dioxide 0-5% volume CO2(IR)

 

XG1-N1-01-AM

Carbon monoxide 0-1000ppm CO

 

XG1-N1-01-AI

Carbon monoxide 0-100ppm CO

 

XG1-N1-01-AN

Carbon monoxide 0-2000ppm CO

 

XG1-N1-01-AJ

Carbon monoxide 0-200ppm CO

 

XG1-N1-01-AK

Carbon monoxide 0-250ppm CO

 

XG1-N1-01-AZ

Carbon monoxide 0-300ppm CO

 

XG1-N1-01-AL

Carbon monoxide 0-500ppm CO

 

XG1-N1-01-AH

Carbon monoxide 0-50ppm CO

 

XG1-N1-01-SE

Chlorine 0-100ppm Cl2

 

XG1-N1-01-SB

Chlorine 0-10ppm Cl2

 

XG1-N1-01-SC

Chlorine 0-20ppm Cl2

 

XG1-N1-01-SZ

Chlorine 0-3ppm Cl2

 

XG1-N1-01-SD

Chlorine 0-50ppm Cl2

 

XG1-N1-01-SA

Chlorine 0-5ppm Cl2

 

XG1-N1-01-AX

Chlorine dioxide 0-1ppm ClO2

 

XG1-N1-01-AY

Diborane 0-1ppm B2H6

 

XG1-N1-01-FP

EDC 0-100%LEL

 

XG1-N1-01-FE

Ethane 0-100%LEL

 

XG1-N1-01-CT

Ethanol 0-100% LEL C2H5OH(IR)

 

XG1-N1-01-FB

Ethanol 0-100%LEL

 

XG1-N1-01-BP

Ethylene 0-100% LEL C2H4(IR)

 

XG1-N1-01-FC

Ethylene 0-100%LEL

 

XG1-N1-01-TC

Ethylene oxide 0-100ppm C2H4O

 

XG1-N1-01-TA

Ethylene oxide 0-10ppm C2H4O

 

XG1-N1-01-TB

Ethylene oxide 0-50ppm C2H4O

 

XG1-N1-01-TD

Fluorine 0-1ppm F2

 

XG1-N1-01-TE

Germane 0-2ppm GeH4

 

XG1-N1-01-CU

Hexane 0-100% LEL C6H14(IR)

 

XG1-N1-01-FY

Hexane 0-100%LEL

 

XG1-N1-01-FA

Hydrogen 0-100%LEL

 

XG1-N1-01-TQ

Hydrogen 0-20000ppm (0-50% LEL) H2

 

XG1-N1-01-AQ

Hydrogen 0-2000ppm H2

 

XG1-N1-01-AP

Hydrogen 0-200ppm H2

 

XG1-N1-01-FS

Hydrogen 0-25%LEL

 

XG1-N1-01-TF

Hydrogen 0-40000ppm (0-100% LEL) H2

 

XG1-N1-01-SW

Hydrogen chloride 0-10ppm HCl

 

XG1-N1-01-SX

Hydrogen chloride 0-25ppm HCl

 

XG1-N1-01-TG

Hydrogen chloride 0-5ppm HCl

 

XG1-N1-01-SY

Hydrogen cyanide 0-25ppm HCl

 

XG1-N1-01-AV

Hydrogen fluoride 0-10ppm HF

 

XG1-N1-01-AG

Hydrogen sulphide 0-1000ppm H2S

 

XG1-N1-01-AC

Hydrogen sulphide 0-100ppm H2S

 

XG1-N1-01-TJ

Hydrogen sulphide 0-10ppm H2S

 

XG1-N1-01-AD

Hydrogen sulphide 0-200ppm H2S

 

XG1-N1-01-TK

Hydrogen sulphide 0-20ppm H2S

 

XG1-N1-01-AE

Hydrogen sulphide 0-250ppm H2S

 

XG1-N1-01-AA

Hydrogen sulphide 0-25ppm H2S

 

XG1-N1-01-AF

Hydrogen sulphide 0-300ppm H2S

 

XG1-N1-01-AB

Hydrogen sulphide 0-50ppm H2S

 

XG1-N1-01-TI

Hydrogen sulphide 0-5ppm H2S

 

XG1-N1-01-FV

hydrogen: 0-10% vol. in air

 

XG1-N1-01-FT

hydrogen: 0-20% vol. in nitrogen

 

XG1-N1-01-TBA

hydrogen: 0-25% vol. in nitrogen

 

XG1-N1-01-TBA

hydrogen: 0-30% vol. in nitrogen

 

XG1-N1-01-TBA

hydrogen: 0-5% vol. in air

 

XG1-N1-01-TBA

hydrogen: 0-50% vol. in air

 

XG1-N1-01-FU

hydrogen: 0-50% vol. in nitrogen

 

XG1-N1-01-FK

IPA 0-100%LEL

 

XG1-N1-01-FR

Jet Fuel 0-100%LEL

 

XG1-N1-01-CV

LPG 0-100% LEL(IR)

 

XG1-N1-01-FW

LPG 0-100%LEL

 

XG1-N1-01-BJ

Methane 0-100% LEL CH4(IR)

XG1-N1-01-FD

Methane 0-100%LEL

XG1-N1-01-BC

Methanol 0-100% LEL CH3OH(IR)

XG1-N1-01-FL

Methanol 0-100%LEL

XG1-N1-01-SP

Nitric oxide 0-100ppm NO

XG1-N1-01-SN

Nitric oxide 0-25ppm NO

XG1-N1-01-SO

Nitric oxide 0-50ppm NO

XG1-N1-01-SM

Nitrogen dioxide 0-100ppm NO2

XG1-N1-01-SK

Nitrogen dioxide 0-10ppm NO2

XG1-N1-01-SL

Nitrogen dioxide 0-50ppm NO2

XG1-N1-01-OA

Oxygen 0-25% vol O2

XG1-N1-01-HA

Ozone 0-1ppm O3

XG1-N1-01-CX

Pentane 0-100% LEL C5H12(IR)

XG1-N1-01-FI

Pentane 0-100%LEL

XG1-N1-01-FN

Petrol Vapour (leaded) 0-100%LEL

XG1-N1-01-FF

Petrol Vapour (unleaded) 0-100%LEL

XG1-N1-01-TN

Phosgene, 0-1ppm 

XG1-N1-01-TM

Phosphine 0-1ppm PH3

XG1-N1-01-BN

Propane 0-100% LEL C3H8(IR)

XG1-N1-01-FH

Propane 0-100%LEL

XG1-N1-01-TP

Silane 0-1ppm SiH4

XG1-N1-01-ST

Sulphur dioxide 0-100ppm SO2 

 

XG1-N1-01-SQ

Sulphur dioxide 0-10ppm SO2

 

XG1-N1-01-SR

Sulphur dioxide 0-20ppm SO2

 

XG1-N1-01-SV

Sulphur dioxide 0-250ppm SO2 

 

XG1-N1-01-SS

Sulphur dioxide 0-50ppm SO2

 

XG1-N1-01-FJ

Toluene 0-100%LEL

 

XG1-N1-01-FO

VCM 0-100%LEL

 

XG1-N1-01-TO

Volatile organics 0-100ppm VO

Accessories:Below is a small selection of the accessories available for the Crowcon Xgard. For a full list please contact Us.   Spray Deflector
  • Spray deflector - C01052 - For outdoor installations and protection from water sprays, for example in water treatment or food processing plants. Includes accessory adaptor. (Not suitable for use with Xgard Type 4)
  Sun Shield
  • Sun shield - C011063 - Protects against excessive heat build-up due to direct sunlight. Supplied with fixing rivets
  Collector Cone
  • Collector Cone - C01051 - For aiding detection of light gases such as methane. 38cm/15″ Dia. Includes accessory adaptor. (Not suitable for use with Xgard Type 4)
    Weatherproof Cap
  • Weatherproof cap - C01442 - For offshore or other extremely wet environments. Includes accessory adaptor. (Not suitable for use with Xgard Type 4)
    Flow Adaptor
  • Flow adaptor - C01339 - For use where a gas sample is being piped to the detector.
    Calibration Adaptor
  • Calibration adaptor - C03005 - To enable calibration gas to be applied to the detector. One adaptor can be used for several detectors.
    Duct Mounting Kit
  • Duct mounting kit - S011918 - Allows sampling within tubes and ducts. Stainless steel plate with 6mm remote calibration fitting. Maximum duct airflow: 6 metres per second. (Not compatible with Stainless Steel Xgard or Xgard Type 4.)

 

Từ khóa » Xg1-n1-01-oa