Flagging Performance Of Sysmex XN-10 Haematology Analyser For ...
- Subscribe
- Log In More Log in via InstitutionLog in via OpenAthensLog in via ACP
Log in using your username and password
For personal accounts OR managers of institutional accounts Username * Password * Forgot your log in details?Register a new account?Forgot your user name or password? - Basket
- Search More Search for this keyword Advanced search
- Latest content
- Current issue
- Archive
- For authors
- About
- Topic collections
- Close More
Main menu
- Latest content
- Current issue
- Archive
- For authors
- About
- Topic collections
- Subscribe
- Log in More Log in via InstitutionLog in via OpenAthensLog in via ACP
Log in using your username and password
For personal accounts OR managers of institutional accounts Username * Password * Forgot your log in details?Register a new account?Forgot your user name or password? - BMJ Journals
You are here
- Home
- Archive
- Volume 73, Issue 10
- Flagging performance of Sysmex XN-10 haematology analyser for malaria detection
Article Text
Article menu- Article Text
- Article info
- Citation Tools
- Share
- Rapid Responses
- Article metrics
- Alerts
- http://orcid.org/0000-0003-0462-2010Cécile Dumas1,
- Pauline Tirard-Collet2,
- Fanélie Mestrallet3,
- Sandrine Girard3,
- Laurent Jallades4,
- Stéphane Picot2,5,
- Anne-Lise Bienvenu1,5
- 1 Service d'Hématologie Biologique, Groupement Hospitalier Nord, Hospices Civils de Lyon, Lyon, France
- 2 Service de Parasitologie et Mycologie, Groupement Hospitalier Nord, Hospices Civils de Lyon, Lyon, France
- 3 Service d'Hématologie Biologique, Groupement Hospitalier Est, Hospices Civils de Lyon, Bron, France
- 4 Service d'Hématologie Biologique, Groupement Hospitalier Sud, Hospices Civils de Lyon, Pierre-Bénite, France
- 5 Malaria Research Unit, SMITh, ICBMS UMR 5246 CNRS, Université de Lyon, Faculte de Medecine Lyon-Est, Lyon, France
- Correspondence to Dr Cécile Dumas, Service d'hématologie biologique - Groupement Hospitalier Nord, Hospices Civils de Lyon, Lyon, France; cecile.dumas{at}chu-lyon.fr
Abstract
Aim The aim was to assess the flagging performance of Sysmex XN-10 haematology analyser for malaria detection through the parasitic red blood cell (‘pRBC’) alarm.
Methods We retrospectively studied 584 blood samples performed on the Sysmex XN-10 analyser that were tested for malaria. Sensitivity, specificity, positive and negative predictive values, and prevalence were established for the pRBC alarm.
Results Sensitivity, specificity, and positive and negative predictive values for the pRBC flag were 7.8%, 100%, 100% and 87.7%, respectively. The prevalence of pRBC flag of 0.026% in the overall population was significantly different from the prevalence of 1.027% in the population tested for malaria.
Conclusions Considering the excellent specificity and the low prevalence of the flag in the overall population, we suggest, in case of the presence of pRBC flag, the implementation of a rapid review of the blood smear looking for Plasmodium, mostly if the patient had fever and had not been tested for malaria.
- malaria
- haematology
- automated screening
- automation
https://doi.org/10.1136/jclinpath-2019-206382
Statistics from Altmetric.com
Request Permissions
If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.
- malaria
- haematology
- automated screening
- automation
Footnotes
Handling editor Mary Frances McMullin.
Contributors CD designed the study. CD, PT-C and A-LB analysed the data and wrote the manuscript. CD, SG, FM and LJ were responsible for the haematological data in the laboratory. PT-C participated in the malaria diagnosis and SP was responsible for the malaria diagnosis. All authors reviewed the manuscript and approved the final version.
Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.
Competing interests None declared.
Patient consent for publication Not required.
Ethics approval Ethical clearance was unnecessary as there was no extra sample required and results were not used for diagnostic purposes.
Provenance and peer review Not commissioned; externally peer reviewed.
Read the full text or download the PDF:
Subscribe Log in Log in via InstitutionLog in via OpenAthensLog in via ACPLog in using your username and password
For personal accounts OR managers of institutional accounts Username * Password * Forgot your log in details?Register a new account?Forgot your user name or password?Read the full text or download the PDF:
Subscribe Log in Log in via InstitutionLog in via OpenAthensLog in via ACPLog in using your username and password
For personal accounts OR managers of institutional accounts Username * Password * Forgot your log in details?Register a new account?Forgot your user name or password?Từ khóa » Xn 10
-
XN-10 Automated Hematology Analyzer With Blood Bank Mode
-
[PDF] XN-10TM - Sysmex Corporation
-
Sysmex XN-10 - SelectScience
-
BK210631 - Sysmex XN-10 Automated Hematology Analyzer - FDA
-
Blast Flagging Of The Sysmex XN-10 Hematology Analyzer ... - PubMed
-
Sysmex America Adds FDA-Cleared XN-10™ Blood Bank Mode To ...
-
XN-1000 - Products Detail - Sysmex Europe
-
Use Of Sysmex XN‐10 Red Blood Cell Parameters For Screening Of ...
-
Blast Flagging Of The Sysmex XN‐10 Hematology Analyzer With ...
-
Sysmex Adds XN-10 Blood Bank Mode To Portfolio - CAP TODAY
-
LR-XN10 - Separate Amplifier Model, Amplifier Units Expansion Unit ...
-
70147381 Rhinoceros XN10-8 - YouTube
-
Sysmex XN Series – RESHAPING SCALABLE AUTOMATION