LR-XN10 - Separate Amplifier Model, Amplifier Units Expansion Unit ...
Digital CMOS Laser Sensor
LR-X series
Catalogues View Catalogue
- Overview
- Specs
- Models
- Downloads
- Price
- Home
- Products
- Sensors
- Photoelectric Sensors
- Digital CMOS Laser Sensor
- Models
- Separate Amplifier Model, Amplifier Units Expansion unit (Zero Line Type)
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
- View Catalogue
- Data Sheet (PDF)
Data Sheet (PDF)
Manuals
CAD Data
360°view (3D PDF)
Dimensions
Software
Specifications
Model | LR-XN10 | |||
Type | — | |||
Cable/connector | ||||
Main Unit/Expansion Unit | Expansion Unit | |||
No. of Control Outputs | None*1 | |||
No. of External Inputs | — | |||
Response Time | 500 μs*2/1 ms/3 ms/10 ms/200 ms Selectable | |||
IO-Link | — | |||
Function | Timer Function | Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot | ||
Input/Output | Control Output | — | ||
External Input | ||||
Unit Expansion | Up to 8 expansion units possible (including main unit, a total of 9 units connected)However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series. | |||
Protection Circuit | Protection against reverse power connection, protection against output overcurrent,protection against output surge, protection against reverse output connection | |||
Number of Interference Prevention Devices | OFF/4 units/8 units selectable*3 | |||
Power supply | Power voltage | 16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2 | ||
Power consumption | During normal operation: 1060 mW (44 mA or less at 24 V, 61 mA or less at 16 V), ECO ON/ALL: 895 mW (37 mA or less at 24 V, 50 mA or less at 16 V) | |||
Environmental resistance | Ambient temperature | −20 to +55°C (no freezing)*5 | ||
Relative humidity | 35 to 85% RH (no condensation) | |||
Vibration resistance | 10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions | |||
Shock resistance | 500 m/s2 (50G); 3 times each for X, Y, and Z axes | |||
Case Material | Main Unit and Cover: Polycarbonate | |||
Accessories | Instruction manual | |||
Weight | Approx. 21 g | |||
*1 This counts as 1 output when expanding with multiple units to the FS-MC8N/MC8P and NU Series.*2 If 500 μs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.· The interference prevention function is not supported*3 Selecting four or eight interference prevention units causes the response time to change as follows: 4 Units selected: 6 ms/18 ms/60 ms/1.2 s selectable; 8 Units selected: 12 ms/36 ms/120 ms/2.4 s selectable.*4 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.*5 Expansion by 1 or 2 units: −20 to +55°C; Expansion by 3 to 10 units: -20 to +50°C, Expansion by 11 to 16 units: -20 to +45°C |
Scroll
Data Sheet (PDF) Other Models
View Catalogue
Downloads:
- Technical Guides
- Data Sheet (PDF)
- CAD Data
- Manuals
- Software
For Your Support:
- Ask KEYENCE
- Experience Demo / Test
- Free Trial Unit
Products Lineup:
- Photoelectric Sensors
- Home
- Products
- Sensors
- Photoelectric Sensors
- Digital CMOS Laser Sensor
- Models
- Separate Amplifier Model, Amplifier Units Expansion unit (Zero Line Type)
- Catalogues
- CAD Data
- Manuals
- Software
- Data Sheet (PDF)
- Price
- Experience Demo / Test
- Ask KEYENCE
Từ khóa » Xn 10
-
XN-10 Automated Hematology Analyzer With Blood Bank Mode
-
[PDF] XN-10TM - Sysmex Corporation
-
Sysmex XN-10 - SelectScience
-
BK210631 - Sysmex XN-10 Automated Hematology Analyzer - FDA
-
Blast Flagging Of The Sysmex XN-10 Hematology Analyzer ... - PubMed
-
Sysmex America Adds FDA-Cleared XN-10™ Blood Bank Mode To ...
-
Flagging Performance Of Sysmex XN-10 Haematology Analyser For ...
-
XN-1000 - Products Detail - Sysmex Europe
-
Use Of Sysmex XN‐10 Red Blood Cell Parameters For Screening Of ...
-
Blast Flagging Of The Sysmex XN‐10 Hematology Analyzer With ...
-
Sysmex Adds XN-10 Blood Bank Mode To Portfolio - CAP TODAY
-
70147381 Rhinoceros XN10-8 - YouTube
-
Sysmex XN Series – RESHAPING SCALABLE AUTOMATION