RECmax MP-C4-10 | CIRCUTOR
- Share
- PDF Datasheet






RECmax MP-C4-10
RECmax MP-C4-10, Motorized circuit breaker,4-pole C-curve
Code: P27121.
- Poles: 4
- In (A): 10 A
- Curve: C
- Information
- Specifications
- Dimensions
- Connections
- Videos
- Downloads
- Accessories
- Support
INFORMATION
Description
The RECmax MP series are motorized circuit breakers that can be linked remotely. They offer protection against short-circuits and overloads, and can also be used as a circuit breaker. After a disconnection caused by a circuit breaker, the switch can be reconnected by an external order. It has two inputs which, via voltage-free external signals, order the opening (input O) and subsequent closing (reclosing) of the circuit breaker (input I). It also features two single-contact outputs for signalling the status and the cause of the opening and closing of the circuit breaker (trip, manual/test).
Applications
The RECmax MP series are motorized circuit breakers that can be controlled remotely, suitable for any application in which remote control of connection/disconnection is required.They are also used as circuit breakers linked to CIRCUTOR self-reclosing relays. They are an essential accessory for automatic circuit breaker and residual current reclosing and protection.
Do you need more information about this product?
If you have any questions, let's talk.
Talk to a specialistSPECIFICATIONS
AC power supply
Nominal voltage230V ~ ± 30%Frequency50 / 60 Hz.Consumption4,5 VAInstallation categoryCAT III 300 VDigital relay outputs
TypeSimple contactsNominal voltage230 V ~Nominal current0,25 AEnvironmental characteristics
Working temperature-20 … +70 ºCRelative humidity (without condensation)5 …95 %Protection classMotor: IP 40 (DIN 40050) / RECmax MP: IP 20Mechanical characteristics
EnvelopePlastic V0 polycarbonate + GFFasteningDIN 46277 (EN 50022)Weight (kg)0,646Size (mm) width x height x depth115 x 110 x 83 (mm)Motor
Nominal voltage230 V ~ ± 30 %Maximum voltage420 V ~Minimum voltage90 V ~On / off pulse time> 10 ms / > 10 msFrequency (Hz)50 / 60Absorbed power10 VATripping / motor reclosure time< 10 ms / < 1000 msElectrical life> 20000 operationsThermal-magnetic protection
V~ Breaking capacity (IEC 60947-2)415 V ~Voltage breaking capacity (IEC 60898)230 / 400 V ~Rated short-circuit breaking capacity (Icn) / service short-circuit breaking capacity (Ics) (IEC 60898)6 kANumber of mechanical / electrical manoeuvres> 20000 / 10000Minimum operating voltage UB min (V)12 V ~Nominal voltage240 / 415 V ~Nominal current In (A)10Trip curve, TypeCAC ultimate short-circuit breaking capacity (Icu) (IEC 60947-2)10 kAStandards
StandardsIEC 60898, IEC 60947-2Electrical safety, Maximum height (m)2000DIMENSIONS
CONNECTIONS
VIDEOS
RECmax: New range of reclosing systems

RECmaxCVM Plug&Play system saves time and space

Saves energy with RECmaxCVM

RECmaxCVM guarantess the electrical continuity from unwanted trippings
DOWNLOADS
Technical guide EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico 3D EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Diagram connection EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Datasheet EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico CE-certified EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Product video EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Catalogue LeafletACCESORIES
SUPPORT
Contacta con nosotros
Envíanos tu consulta y contactaremos contigo.
¿Quieres comprar?
Contacta con nuestra red comercial o busca tu distribuidor cercano.
TAMBIÉN TE PUEDE INTERESAR
CONTACT
Vial Sant Jordi s/n – 08232 Viladecavalls, Barcelona (Spain) +34 93 745 29 00 Contact
SAT
After-Sales and Technical Assistance +34 93 745 29 19 Send enquiry
EXPERTS IN
- Electrical energy efficiency
- Harmonic filtering
- Electrical protection
- Energy measurement
- Self-consumption
- Energy audit
- Internet of Things
PRODUCTS
- Measurement and control
- Metering
- Protection and control
- Power factor correction and harmonic filtering
- Renewable energies
- Software
- Industrial IoT and Automation
CONNECT
INFORMATION
- Privacy policy
- Cookies policy
- Use of social networks
- General conditions of sale
- Legal notice
- Code of ethics
© 2024 CIRCUTOR.COM | All rights reserved.
Từ khóa » C4/10
-
Error Codes > Sharp > MX3100N > Code C4-10 - PrintCopy .info
-
KIT-C4-10-EPR Parker | Check Valve Repair Kit
-
Epson LabelWorks LW-C410 | Label Printers And Presses
-
AF C4.10 Bit | Audison - Car Audio Processors, Amplifiers And Speakers
-
CITROEN C4 '10 COOLING COIL -LHD - EMAS Website
-
All-Clad C4110 C4 10 In. Fry Pan, Cookware, Copper
-
RECmaxLPd-C4-10 | CIRCUTOR
-
M10 C4-10 10" Waterpump Plier - Li Fong Hardware Enterprise