RECmaxLPd-C4-10 | CIRCUTOR

Có thể bạn quan tâm

Circutor
ESENFRPTCAMX HomeProductsMCB and residual current protection with self-reclosingSelf-reclosing residual current relay with circuit breaker, used with an external residual current transformer, 4 poles C curveSelf-reclosing residual current relay with circuit breaker, used with an external residual current transformer, 4 poles C curve
  • Share
  • PDF Datasheet
Overcurrent +residual current protectionOvercurrent +residual current protectionOvercurrent +residual current protectionOvercurrent +residual current protectionOvercurrent +residual current protectionOvercurrent +residual current protection

RECmaxLPd-C4-10

RECmaxLPd-C4-10, Motorized circuit breaker,4-pole C-curve

Code: P2A121.

  • Poles: 4
  • In (A): 10 A
  • Breaking element: built-in
  • Curve: C
  • Information
  • Specifications
  • Dimensions
  • Connections
  • Videos
  • Downloads
  • Accessories
  • Support

INFORMATION

Description

Self-resetting cut-off device with circuit breaker and ultra-immunised residual current protection. Programmable unit with display, which measures leakage currents (residual current protection), and orders the disconnection or reclosing of the circuit breaker (circuit breaker protection) by means of a motor that regulates it mechanically. Measuring the leakage current, IΔ, requires an external residual current transformer, which is supplied separately.  The assembly is regularly used in single-phase and three-phase electrical installations that require high continuity of the electric supply. It has inputs/outputs which provide information and control of the state of the electrical installation in which it is working. LED display and backlit (LCD) display:

  • Residual current protection/reclosing parameters.
  • Protection trip current intensity.
  • Number of reclosures
  • Protection status messages, etc.

Applications

The RECmax LPd, linked with the WGC toroidal transformers, ensures earth-leakage and circuit-breaker protection with self-reclosing after an residual current, overload or short-circuit trip. It is a good solution for infrastructures that are difficult to control and monitor due to their location in the following electric panels:

  • Telephony systems
  • DTT systems
  • Computer systems, UPS

Do you need more information about this product?

If you have any questions, let's talk.

Talk to a specialist

SPECIFICATIONS

AC power supply
Nominal voltage230V ~ ± 30%Frequency50/60 HzConsumption5 VAInstallation categoryCAT III 300 V
User interface
Display typeLCDLED2 LEDKeyboard3 keys
Environmental characteristics
Working temperature-20 … +70 ºCStorage temperature-40 … +75 ºCRelative humidity (without condensation)5 … 95 %Protection classIP 20, IP 41 (rear panel)
Mechanical characteristics
EnvelopePlastic V0FasteningDIN railWeight (kg)0,64Size (mm) width x height x depth115 x 110 x 83 (mm)
Differential protection
Sensitivity (I∆n), A0,03 (por defecto) / 0,1 - 0,3 - 0,5 - 1 A (programable)Delay time (t∆)Trip delay (IEC 60947-2-M) INS / SEL
Reclosure type
Reset timeProgrammable: Differential / Magnetothermic: 30 minReclosure timeProgrammable: Differential / Circuit breaker: 3 minReclosure numberProgrammable: Differential (10) / Magnetothermal (2)
Thermal-magnetic protection
V~ Breaking capacity (IEC 60947-2)415 V ~Voltage breaking capacity (IEC 60898)230 / 400 V ~Rated short-circuit breaking capacity (Icn) / service short-circuit breaking capacity (Ics) (IEC 60898)6 kANominal voltage240 / 415 V ~Nominal current In (A)10Trip curve, TypeCAC ultimate short-circuit breaking capacity (Icu) (IEC 60947-2)10 kA
Standards
StandardsIEC TR 60755, IEC 60898-1, DIN EN 50022, IEC 60947-2-MElectrical safety, Maximum height (m)2000

DIMENSIONS

CONNECTIONS

VIDEOS

RECmax: New range of reclosing systems

RECmaxCVM Plug&Play system saves time and space
Saves energy with RECmaxCVM
RECmaxCVM guarantess the electrical continuity from unwanted trippings

DOWNLOADS

User's manual EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Technical guide EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico 3D EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Diagram connection EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Datasheet EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico CE-certified EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Product video EspañolEnglishFrançaisPortuguêsCatalàSpanish, Mexico Catalogue Leaflet

ACCESORIES

SUPPORT

Contacta con nosotros

Envíanos tu consulta y contactaremos contigo.

¿Quieres comprar?

Contacta con nuestra red comercial o busca tu distribuidor cercano.

TAMBIÉN TE PUEDE INTERESAR

CONTACT

Vial Sant Jordi s/n – 08232 Viladecavalls, Barcelona (Spain) +34 93 745 29 00 Contact

SAT

After-Sales and Technical Assistance +34 93 745 29 19 Send enquiry

EXPERTS IN
  • Electrical energy efficiency
  • Harmonic filtering
  • Electrical protection
  • Energy measurement
  • Self-consumption
  • Energy audit
  • Internet of Things
PRODUCTS
  • Measurement and control
  • Metering
  • Protection and control
  • Power factor correction and harmonic filtering
  • Renewable energies
  • Software
  • Industrial IoT and Automation
CONNECT

INFORMATION
  • Privacy policy
  • Cookies policy
  • Use of social networks
  • General conditions of sale
  • Legal notice
  • Code of ethics

© 2024 CIRCUTOR.COM | All rights reserved.

Từ khóa » C4/10