British Standard BS 476 Part 7 Fire Test

BS 476 refers to the British standard for fire tests on building materials and structures. This test standard is split into two parts: Part 6 and Part 7. Part 7 specifies the test method for measuring the lateral spread of flame along the surface of a test specimen.

How is Part 7 tested?

The setup: A combustion chamber containing a horizontal gas burner tube and two electrical heating elements is placed below a removable steel chimney and cowl (specimen holder). The specimen is placed in a vertical test position adjacent to the radiation panel, within 5 seconds of igniting a pilot flame.

The procedure: The specimen is set on fire by a pilot flame and this flame is extinguished after a minute. The material might start to burn and the test is terminated when the flame front reaches the 825mm reference line, or after 10 minutes has lapsed, whichever is earlier.

The result: During the test, the following measurements are recorded:

  • Time at which the flame front crosses each vertical reference line
  • Maximum extent of flame spread during the first 1.5 minutes from the start of the test
  • Maximum extent of flame spread during the whole test (i.e. 10 minutes or less, where applicable)
  • Time (and distance) at which the maximum flame spread reached.

The flame spread at 1.5 minutes and the final flame spread results are compared with the standard class limits as shown in figure below and a classification is assigned.

Reference lines to assist surface spread of flame classification
Reference lines to assist surface spread of flame classification

What does this mean for my project?

Materials that conform to BS476 provides added assurance about the materials contributing to the overall safety of building occupants in the event of a fire.

If Class 1 classification is required, look out for materials that have been tested according to BS 476 Part 7.

If Class 0 classification is required, the material must either:

  • Be composed throughout of materials of limited combustibility, or
  • Tested to be a Class 1 material (classified if the material passes the Part 7 test) AND passes the Part 6 test where it has a fire propagation index (I) of not more than 12 and sub-index (i1) of not more than 6.

More on safety standards

Armacell Know-how // BS 476 Part 7

BS 476 refers to the British Standard for fire tests on building materials and structures. Part 7 specifies the test method for measuring the lateral spread of flame along the surface of a test specimen. During the test, the measurements recorded include... Read more

Armacell Know-how // BS476 Part 6

BS 476 refers to the British Standard for fire tests on building materials and structures. Part 6 specifies a method of test for providing a comparative measure of a flat material/assembly's contribution to the growth of a fire. It takes into account the combined effect of factors such as... Read more

Armacell Know-how // FM 4924

The FM approval is an approval requirement for insulation material used on the exterior of non-combustible pipes or ducts. This standard uses a full-scale test for pipe and sheet insulation. Tests in this standard are different from the BS 476 standard as... Read more

Armacell Know-how // NFPA 274

The NFPA 274 Standard Test Method is a full-scale test that uses large samples to simulate how insulated pipes in a confined vertical configuration may behave during a growing fire situation. It may be a more realistic assessment as it reflects the actual... Read more

< Return to Armacell Know-how

Write to Us

Contact Page for Armacell Singapore Company* Contact Person* Contact Number* E-Mail Address* Country* Please select country Afghanistan Albania Algeria Andorra Angola Antigua & Deps Argentina Armenia Australia Austria Azerbaijan Bahamas Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bhutan Bolivia Bosnia Herzegovina Botswana Brazil Brunei Bulgaria Burkina Burundi Cambodia Cameroon Canada Cape Verde Central African Rep Chad Chile China Colombia Comoros Congo Congo {Democratic Rep} Costa Rica Croatia Cuba Cyprus Czech Republic Denmark Djibouti Dominica Dominican Republic East Timor Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Ethiopia Fiji Finland France Gabon Gambia Georgia Germany Ghana Greece Grenada Guatemala Guinea Guinea-Bissau Guyana Haiti Honduras Hungary Iceland India Indonesia Iran Iraq Ireland Israel Italy Ivory Coast Jamaica Japan Jordan Kazakhstan Kenya Kiribati Korea North Korea South Kosovo Kuwait Kyrgyzstan Laos Latvia Lebanon Lesotho Liberia Libya Liechtenstein Lithuania Luxembourg Macedonia Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Mauritania Mauritius Mexico Micronesia Moldova Monaco Mongolia Montenegro Morocco Mozambique Myanmar, Namibia Nauru Nepal Netherlands New Zealand Nicaragua Niger Nigeria Norway Oman Pakistan Palau Panama Papua New Guinea Paraguay Peru Philippines Poland Portugal Qatar Romania Russian Federation Rwanda St Kitts & Nevis St Lucia Saint Vincent & the Grenadines Samoa San Marino Sao Tome & Principe Saudi Arabia Senegal Serbia Seychelles Sierra Leone Singapore Slovakia Slovenia Solomon Islands Somalia South Africa South Sudan Spain Sri Lanka Sudan Suriname Swaziland Sweden Switzerland Syria Taiwan Tajikistan Tanzania Thailand Togo Tonga Trinidad & Tobago Tunisia Turkey Turkmenistan Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States Uruguay Uzbekistan Vanuatu Vatican City Venezuela Vietnam Yemen Zambia Zimbabwe Message* I consent to the collection, use and disclosure of personal data in accordance with and for the purposes set forth in Armacell's Privacy Policy. Don't fill this field!
BS 476 Part 7 test chamber
BS 476 Part 7 test chamber

Discover products

ArmaFlex Class 0
ArmaFlex Class 1
NH/ArmaFlex
GET SOCIAL Copyright © 2015-2024 Armacell - All rights reserved.
To use the Armacell Website with the best user experience and all functions, we recommend that you install a newer browser:

Firefox, Chrome, Internet Explorer

Từ khóa » Tiêu Chuẩn Bs 476 Part 7